Fault Performance |
Cause Analysis |
Troubleshooting Method |
Hydraulic system not functioning |
Air leakage in the pipeline system |
Seal the leaking pipe section |
Pneumatic piston of the power take-off is stuck |
Remove the obstruction |
|
Damage at the connection between the power take-off and the oil pump |
Replace |
|
Electronic control system not functioning |
Grounding in the circuit, fuse blown |
Check the circuit and replace the fuse |
Disconnection in the system circuit |
Inspect the circuit and reconnect the disconnection |
|
Cylinder stroke reduced |
Insufficient hydraulic oil |
Refill oil |
Insufficient hydraulic system pressure or pressure fails to rise |
Low oil pump speed |
Check engine speed |
High oil temperature, viscosity reduced |
Operate after oil temperature lowers |
|
Overflow valve malfunction |
Clean, repair, or replace |
|
Large flow pulsation or pressure pulsation |
Significant air mixed in the oil |
Release air or replace with new oil |
Directional control valve malfunction |
Repair or replace |
|
Severe noise |
Air intake or air mixed in |
Identify and eliminate the cause |
Clogged filter causing oil pump suction loss |
Clean the filter |
|
Cylinder fails to perform sequential actions |
Foreign object blocking the proximity switch |
Remove the foreign object |
Proximity switch installation is loose |
Tighten the proximity switch |
|
Cylinder does not move |
Directional control valve fails to switch |
Repair or replace |